Direct attach copper
DAC
Passive, in-rack. No added latency.
800G to 4 m · 1.6T to 1 m

Passive and active copper where the distance is short and the budget is power.
Fibre from the row to the spine, where copper runs out of reach.
800G is mainstream for AI clusters today. 1.6T is ramping.
Photonics & AI data centres
An AI cluster is only as fast as the links between its GPUs. We are India’s partner for the copper and optical interconnect that carries that traffic — supplying and designing it in today, and building the capability to manufacture it here.
Reach
Typical maximum reach by media type. Indicative figures — actual reach depends on speed, cable construction and the link budget you design to.
Log scale · copper fades at its reach · optics keeps going
Inside an 800G module
Illustrative. Not a specific vendor’s product.
The right answer at every reach
Scale-up inside the rack, scale-out between racks, scale-across the fabric. Every link gets the medium its distance and power budget call for — and nothing it does not.
< 5 W
800G multimode LPO, per end
Linear pluggable optics, no DSP. In mass production.
9 m
800G on copper
Retimed AEC. Up to 4 m at 1.6T.
1.6T
2×DR4 / DR8 LPO
Silicon photonics, 500 m single-mode.
1M+
Units shipped in 2024
Automated lines, 150 units an hour at over 98% yield.
| Built on | 800G | 1.6T | Where it goes | |
|---|---|---|---|---|
| DAC | Passive copper | 4 m | 1 m | In-rack, GPU to switch. Lowest power and cost per link, no added latency. |
| ACC | Linear redriver | 5 m | 3 m | Adjacent racks and xPU-to-xPU, keeping copper's cost and power. |
| AEC | Retimer / DSP | 9 m | 4 m | Row-level copper. The reach that keeps a rebuild out of the plan. |
| AOC | VCSEL optics, LPO or retimed | SR 100 m | — | Rack-to-rack and across the row, where copper should stop. |
| Pluggable optics | Multimode and single-mode | SR 100 m · DR 500 m · FR 2 km | DR8 500 m · FR8 2 km | Leaf to spine and across the hall. Reconfigurable. |
| Coherent | Coherent optics | Coming | Coming | Longest reach, between halls and buildings. |
Start from
A linear redriver extends copper past DAC reach while keeping copper's cost and power.
Also reaches 5 m: AEC · AOC (LPO) · SR8 LPO optics
Get a written link planIndicative, from published maximum reach. Your link budget, cable build and thermals decide the final answer.
Portfolio
Supplied through our USA technology partner.
Direct attach copper
Passive, in-rack. No added latency.
800G to 4 m · 1.6T to 1 m
Active copper cable
Linear redriver, for xPU-to-xPU links.
800G to 5 m · 1.6T to 3 m
Active electrical cable
Retimer / DSP. Copper at row reach.
AEC: up to 9 m at 800G (partner specification)
Active optical cable
Optical reach inside the hall, LPO or retimed.
200G – 800G · to 100 m
Multi-mode and single-mode
LPO and full-retimed, SR to FR — 67 models.
400G · 800G · 1.6T
Structured fibre
Trunks, breakouts, shuffle boxes and fibre array units.
Rolling out
Ethernet and InfiniBand.
Indicative direction, not dated commitments.
Linear pluggable optics
An LPO module drives the laser straight from the switch SerDes, with no DSP or CDR in the module. That takes out the part that burns the most power and adds the most latency, and lowers the cost per port.
Under 5 W per end at 800G multimode and about 3 W at 400G. Across a few thousand ports, the watts a DSP would have burned go back to the GPUs.
Full-retimed (DSP) optics stay the safer choice where the host SerDes is marginal or the link budget is tight. The catalogue carries both, so the choice is made per link rather than per vendor.
| Models | 67 pluggable transceivers · 16 AOCs · 27 each of DAC, ACC, AEC |
|---|---|
| Data rates | 400G · 800G · 2×400G · 1.6T |
| Lane rates | 50G, 100G and 200G per lane (PAM4) |
| Architectures | Full-retimed (DSP) and linear pluggable (LPO) |
| Reach classes | SR4 / SR8 to 100 m · DR4 / DR8 to 500 m · FR4 / FR8 to 2 km |
| Form factors | OSFP (flat-top, RHS, closed-top) · QSFP-DD · QSFP112 · QSFP56 · breakouts |
| Cooling | Air, liquid and immersion, single- and two-phase coolant |
| Management | CMIS 4.0 and 5.x · Class 1 laser |
Interoperability
The best specification does not matter if the ecosystem cannot keep up. Every design is qualified on current test systems and for interoperability on production switches, by third parties as well as in the lab.
Broadcom Tomahawk 6 platforms, NVIDIA Spectrum Ethernet and Quantum InfiniBand switches.
NVIDIA ConnectX-8 800G SuperNIC, ConnectX-9 and BlueField-4, in Ethernet and InfiniBand.
Passed CMIS 5.3 compliance and interop at the 43rd InfiniBand and RoCE Plugfest (IBTA / UNH-IOL), at 800G and 1.6T.
Links proven on Keysight and VIAVI test systems — 800G copper at 9 m holding pre-FEC BER better than 1E-8.
31 loopback modules from 25G to 1.6T, SFP56 through OSFP-XD — passive at 0 W, or active up to 60 W to load a port thermally the way a real module does. The fastest way to qualify a switch before the optics arrive.
Design to volume
Design is part of the work, but it is not the point. The point is everything that turns a design into a qualified product running in your cluster — and the capacity to deliver it in volume.
Start from a proven design on leading silicon, matched to the reach, power and timeline of your cluster — not a catalogue to sort through.
The design is stood behind. When a build genuinely needs something custom, the engineers design and qualify it.
Make it work in your environment before deployment: signal integrity, link margin, thermals and interop, on your switches.
Once qualified, it is manufactured in volume — from ten units to the millions — on your timeline.
AI-driven production and test lines. 150 units an hour at over 98% yield on the copper lines.
From ten units to the millions the largest deployments need, with capacity stood up in weeks rather than quarters.
Production replicated across North America and Asia, so no single region is the one your supply depends on — and country-of-origin requirements can be met without re-engineering.
India
Gigawatts of installed capacity
MeitY (2020 and 2025 actuals, Mar 2026); Savills India (Jul 2025); Colliers (May 2025); Wood Mackenzie via IANS (Jul 2026). Forecasts differ widely — treat 2030 as a range.
Operational capacity. Source: MeitY reply in Lok Sabha (Mar 2026). Schematic layout — positions are indicative, not a survey map.
Interconnect is a local business: someone has to be on site when a cluster is qualified, and on the phone in the same time zone when it is not. Four of those five markets are cities where we have team members.
Our model
Our USA technology partner builds the interconnect. Praverse does the Indian architecture, design-in, integration, qualification and support, for sovereign AI data centres.
Each phase is unlocked by customer demand, so capacity arrives when India’s AI build-out needs it — not before.
Our team works from the cities that hold most of India’s data-centre capacity, close to where deployments happen. Vadodara to Mumbai is about 400 km.
Built around the DPDP Act 2023.
Design-in and qualification happen in India.
On the same clock as you.
Roadmap
PHASE 1 · NOW
Interconnect supplied with our US technology partner, with India-side programming, testing, labelling and qualification, and support on local time.
PHASE 2 · NEXT
Assembly of semi-finished interconnect in India, close to the clusters being built.
PHASE 3 · PLANNED
An Indian manufacturing facility for copper interconnect first, then optical, as volumes justify it.
Phases 2 and 3 are plans, not facilities. We will not show you a factory we do not have, and we will not quote a location, a capacity or a date until one is signed.
Send us the topology and the distances. You get a written plan within two business days.